TECHNOPOOL
Dosing systems for swimming pools ENGLISH
ADSP7000570 rev. 2.0 06/08/2021 26/37
5.2 RESTORE THE DEFAULT PARAMETERS
The restoration of the factory parameters is enabled (refer to appendix 1). The
system asks if you are sure to proceed.
Press keys ▼▲ to select the two options and Enter to confirm.
By activating this function, all programmed data will get lost!
6.0 ALARMS
The system is equipped with the following alarms:
▪ Level alarm, with 3 seconds of hysteresis; this alarm interrupts the operation of the relative pump.
▪ Flow alarm, with 3 seconds of hysteresis; this alarm interrupts the dosing of the system.
▪ Dosing enabling alarm, with 3 seconds of hysteresis; this alarm interrupts the dosing of the system.
▪ pH measure alarm: The system is equipped with a pH reading alarm. If the value of the pH is lower
than 5 and higher than 9, the system stops the pumps. If the value of pH is lower than 5 or higher than
9, it is recommended to control the probe and the quality of the water.
▪ Dosing Alarm: product dose with no effect (with no variation in the pH or Rx or Cl or HP reading). The
dosing alarms can only be removed by restarting the system (use the ON/OFF switch) or automatically,
when the measure nears the setpoint.
6.1 SETTING THE ALARMS
Select Alarms in the installer menu.
Contr. Dos. (V1)
Enables or disables the dosing, when signal V1 occurs (signal of the
active recirculation pump).
Press keys ▼▲ to select the two options and Enter to confirm.
Flow control
Enables or disables the dosing, when water flow occurs.
Press keys ▼▲ to select the two options and Enter to confirm.
pH dosing alarm
This is a dosing alarm and if the pH pump doses the product and there is
no variation in pH (0.05 pH) during the set time, the system signals the
alarm and stops dosing.
The alarm is automatically disabled when the setpoint is neared (when the
difference between the pH measure and the setpoint is less than 0.2 pH).
Use the ▼▲ keys to set the desired value or disable the alarm (Off) and
then confirm with the Enter key.
The time values that can be set are 5÷60 minutes.
Rx dosing alarm
(only for technopool3 Time/pH/Rx and pH/Rx)
This is a dosing alarm and if the Rx pump doses the product and there is
no variation in Rx (5 mV) during the set time, the system signals the alarm
and stops dosing.
The alarm is automatically disabled when the setpoint is neared (when the
difference between the pH measure and the setpoint is less than 20 mV).
Use the ▼▲ keys to set the desired value or disable the alarm (Off) and
then confirm with the Enter key.
The time values that can be set are 5÷60 minutes.