Connect the hose to the bottom of the valve outlet ensuring the hose washer is correctly fitted to allow the water to
discharge safely to waste and run the shower for a few seconds to clear any debris in the outlet assembly.
10
Turn off the shower and pass the hose through the hose restraint.
11
Disengage the pivot clip and remove the pivot from the bottom of the handset.
12
Ensure the hose washer is in the correct position and screw the pivot into the hose, using a
suitable hexagonal key to tighten, taking care not to over-tighten. Reinsert the pivot into the
handset and engage the pivot clip prior to placing the handset into the handset holder.
8
If required, optional outlet flow regulators can be purchased from the Aqualisa customer helpline on 01959 560010.
Fit the relevant flow regulator into the brass housing ensuring the O’ring faces the incoming flow. Connect the flow
regulator assembly to the valve outlet ensuring the hose washer is correctly fitted.
!
Outlet flow regulators are not suitable for products fitted to combination boiler systems.