200-0162
March 2007
USERS’ INSTALLATION
OPERATION and
MAINTENANCE MANUAL
Optima 70 - 2
Gas Fired Vented Room
Heater (Direct Vent)
For use with natural gas or propane*
7116 Beatty Dr
Mission, BC V2V 6B4
Canada
Installer: Please leave this manual with the appliance owner for future reference
This appliance may be installed in an
aftermarket permanently located,
manufactured home (USA only) or mobile
home, where not prohibited by local codes.
This appliance is only for use with the type
of gas indicated on the rating plate. This
appliance is not convertible for use with
other gases, unless a certified kit is used.
*Conversion kit required for Propane use
WARNING: If the information in this manual is not
followed exactly, fire or explosion may result
causing property damage, personal injury or loss
of life.
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch; do not use
any phone in your building.
Immediately call your gas supplier from a
neighbor’s phone. Follow the gas supplier’s
instructions.
If you cannot reach your gas supplier, call the
fire department.
Installation and service must be performed by a
qualified installer, service agency or the gas
supplier.

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Archgard Optima 70-2 and is the answer not in the manual?

Archgard Optima 70-2 Specifications

General IconGeneral
BrandArchgard
ModelOptima 70-2
CategoryHeater
LanguageEnglish

Summary

Safety and Cautionary Information

General Safety Precautions and Warnings

Crucial safety advice for operation, placement, and handling the appliance.

Appliance Compliance and Specifications

Appliance Certification and Safety Standards

Details US and Canadian safety approvals for the appliance.

Installation Codes and Standards Compliance

Outlines adherence to national and local installation codes.

Gas Connections and Pressure

Gas Connection Procedures and Safety Checks

Steps for connecting the gas supply and checking for leaks.

Natural Gas and Propane Pressure Settings

Specifies required pressure settings for different gas types.

Venting System Installation

Approved Vent Components and Systems List

Lists approved vent parts and systems for the Optima 70.

General Venting Connection Rules and Guidelines

Provides essential guidelines for safe and effective venting.

Vertical Venting Configuration

Vertical Venting Configuration Chart and Rules

Illustrates allowed combinations of vertical height and horizontal length for venting.

Vertical Termination Using Simpson Dura-Vent Pipe

Vertical Termination with Simpson Dura-Vent Pipe

Step-by-step guide for vertical venting using the Simpson Dura-Vent pipe system.

Vertical Termination Using Flex Gas Liner

Vertical Termination Using Flex Gas Liner

Instructions for venting vertically with flexible gas liner.

Horizontal Venting with Flexible Direct Vent Systems

Horizontal Venting with Simpson Dura-Vent Systems

Simpson Dura-Vent Horizontal Venting Installation Procedures

Installation guide for horizontal venting using the Simpson Dura-Vent system.

Electrical Connections and Fan System

Fan System Electrical Connections and Wiring

Instructions for connecting the fan system and wiring details.

Installation Completion and First Use

Final Installation Checks and Verification

Checklist for ensuring proper installation before appliance operation.

Initial Appliance Operation and Checks

Steps for starting the fireplace for the first time and initial checks.

Initial Burn-in and Lighting

First Fire Procedure and Initial Odor Information

Guidelines for the initial burn-in period and expected odors.

Pilot and Burner Lighting Safety Instructions

Steps for lighting the pilot and main burner safely.

Lighting Instructions from Rating Plate

Lighting Instructions from Rating Plate

Detailed pilot and burner lighting steps from the appliance rating plate.

Gas Leak Detection and Emergency Procedures

Critical steps to follow if a gas smell is detected.

Troubleshooting Common Issues

Troubleshooting Pilot and Burner Ignition Issues

Common problems with pilot ignition and main burner operation.

Appliance Maintenance and Care

Servicing and Air Adjustment

Flame and Orifice Adjustments

Gas Pressure and Pilot Checks

Checking Inlet and Outlet Gas Pressure

Procedure for measuring inlet and outlet gas pressures.

Component Replacement Procedures

Archgard Limited Warranty Information

Archgard Limited Warranty Coverage and Terms

Details on warranty coverage, exclusions, and limitations.