Rating data
Power supply 220-240 V – 50 Hz
Minimum power input 4 watt
Max power input without connected electrical elements 70 watt
Max power input with connected electrical elements 3x1500 watt
Water connection 3/4” G – 3/4” G
Refrigerant connection (R410A) 3/8” – 3/8”
Net weight 16,5 Kg
Dimensions (H/W/D) 272x527x285
A 3/4” water  lter is supplied with Emix to be installed upstream of tap water connection. It is warmly suggested to
install a softener or a polyphosphate  lter to avoid limestone and consequently loses of performance; in addition to this
service valves, mixing valve and overpressure valve are suggested.
How to install Emix
Emix works only with an iSeries outdoor unit system; it is commonly connected to the proper EMX port but could be
connected also to a normal port like AEI1G30EMX/GR9FI30R5IBA that has an adapter from 3/8” to 1/4” for the liquid
return  are.