12. Automatic Cycle Mode
In the Automatic cycle mode, all the operations (Refrigerant Recovering and Recycling,
Recovered Oil Drain, Evacuation and Refrigerant Charging) are performed automatically
one after the other in ONE CYCLE.
Note: During AUTOMATIC mode hand valves (4) on the console must be open.
To initiate the Automatic cycle mode, press the “UP” or 'DOWN' key 4 times (display will show
AUTO) followed by 'START' key.
Set the vaccum time duration by pressing the 'UP' key to increase or 'DOWN' key to decrease.
Once the desired vacuum time has been selected, press 'START' key.
(example value only)