3. Technical Specifications
Refrigerant ....................................... R134 a
Electronic refrigerant scale ................ +/- 10 g resolution
Load cell .......................................... 60kg with 150% overload capacity
LP and HP gauges ............................ AI-D 68 mm kl.1.0
Recovery pump ................................ Danfoss TL5G, hermetic
Recovery rate ................................... 220 g/min (liquid state)
Vacuum pump .................................. 50 l/min (1.5 cfm)
Dimensions ...................................... 43.5cm x 40cm x 45cm (height)
Weight .............................................. 34kg (without hoses and cylinder)
Chassis ............................................. Sturdy all steel construction, powder coated.
Supply voltage .................................. 220-240VAC / 50-60Hz
Power .............................................. 500 W
Noise level ........................................< 70 dB (A)
Working conditions ............................ 0 – 45
o
C ambient temperature, up to 80%
humidity, 2000m altitude