5. Display descriptions
Other display descriptions:
FILT XXHr - Displays filter life in number of hours after machine is switched on
O Hr – Service alarm for maintenance and filter replacement.
PAUS - Recovery pause is running, for duration of two minutes.
bUSY – Recovered (old) oil drain into plactic vessel (9)
dOnE - The selected function is completed
nO rEF - No refrigerant pressure in service hoses, or console hand valves are not open
HIgH PrES - Excess pressure in refrigerant cylinder (12)
CYL FULL - Refrigerant weight exceeds maximum allowable limit and will not recover any more
refrigerant
TArE - Calibrating the weight display to read -0.00 with an empty cylinder on platform.
SPAn - Calibrating of the refrigerant electronic scale
CYL - This display allows the operator to set the maximum allowable refrigerant weight in
cylinder.
Err1 - Disconnected load cell lead or faulty load-cell.
selected also.