14. Service Procedure
The following table describes the service intervals of the unit.
Every 100 Working Hours /Once a Year Service.
The service alarm will alert the operator for maintenance and filter replacement.
Service Kit 100Hr
- Vacuum pump Oil - 330ml,
- Recovery Line Filter Strainer,
- Main Filter Dryer,
- Service Hoses Rubber Gaskets
Interval
Component
Procedure
Every 100 Hr / Once a year
Main Filter Dryer
Replace
Every 100 Hr / Once a year
Primary Recovery Line Filter Strainer
Replace
Every 100 Hr / Once a year
Vacuum Pump Oil – 250ml
Drain and refill
Every 100 Hr / Once a year
Service hose Rubber Gaskets
Check / Replace
Every 100 Hr / Once a year
Gauges
Test calibration
Every 100 Hr / Once a year
Weight Platform
Test calibration
Every 300 Working Hours Service.
The unit requires 100 hour service plus replacing of oil separator, primary charging filter and
recovery pump (compressor) oil.
Interval
Component
Procedure
300 Hours
Oil Separator
Replace
300 Hours
Primary Charging Line Filter Strainer
Replace
300 Hours
Recovery Pump Oil – 280ml
Drain and refill
300 Hours
Main Filter Dryer
Replace
300 Hours
Primary Recovery Line Filter Strainer
Replace
300 Hours
Vacuum Pump Oil - 250ml
Drain and refill
300 Hours
Service hose Rubber Gaskets
Check / Replace
300 Hours
Gauges
Test calibration
300 Hours
Weight Platform
Test calibration
Service Kit 300Hr
- Vacuum pump Oil - 330ml,
- Recovery Line Filter Strainer,
- Main Filter Dryer,
- Service Hoses Rubber Gaskets,
- Charging Line Filter strainer,
- Oil Separator,
- Recovery Pump Oil - 500ml
Manufacturer recommends a record of all services on the machine to be kept.