Loading...
Supplied By www.heating spares.co Tel. 0161 620 6677
38
once
Factory
setting
DISPLAY
ACTION CONFIGURATION
x times
Section Digit 1 Digit 2 Digit 3 and 4
Stop pump after burner stops 4 0
0 : no
1 : yes
Pump speed 4 1
0 : High speed
1 : Adaptive
Pump post circulation duration 4 2
0 to 5 min by step
0.5 min
Inactive 4 3
Maximum Central Heating flow
temperature
4 4
50° to 85°
by steps of 1°
Minimum Central Heating flow
temperature
4 5
25° to 50°
by steps of 1°
Inactive 4 6
Inactive 4 7
CH anti-cycling delay 4 8
0 to 7 min by step
0.5 min
CH maximum output (range rating) 4 9
Value from 0 to 10
Pmin & Pnominal