Menu - 5 - Combustion rate control mode (test mode)
Effect Display
The combustion rate control mode will be inactive when :
- boiler is in stand by mode
- heating mode with room thermostat and initial heating temperature reaches max. heating recommendation
- boiler in lockout mode
- after the default settings have been restored or if the main supply fails (power cut)
- if the operator exits the 5th menu
- after 5 minutes if no buttons are pressed
Note : As soon as the combustion rate control mode is active, the Central Heating and Domestic Hot Water
control knobs become inactive.
DISPLAY
ACTION CONFIGURATION
Combustion rate control mode OFF
Combustion rate control mode ON The main exchanger temperature
appears on the display.
The digit - on the display shows the gas
output level.
(Top = max, bottom = min).
Gas output setting To modify the gas output use the + and -
buttons.
To cancel the combustion rate control mode press the “Menu” button.
once