DISPLAY
ACTION CONFIGURATION
once
x times
Factory
setting
N.B.
To ensure that these parameters are set correctly, consult the "thermo-regulation help" document enclosed with the
documentation folder.
Menu - 6 - Thermo-regulation settings
Section Digit 1 Digit 2 Digit 3 and 4
Type of control 6 0
0: Heating setting can be
adjusted by the user
1: Variable heating setting
depending on the external
temperature
2: Variable heating setting
depending on the room
temperature (Clima Manager)*
3: Variable heating setting
depending on the external and
room temperatures (Clima
Manager)*
Compensation 6 1
If or
00 to 20 in intervals of 1
Slope 6 2
If or
0.3
0.5
1.0
1.2
1.5
2.0
2.5
3.0
Parallel shift 6 3
If or
from - 20 to 20 in intervals of 1
Inactive 6 4
--
Inactive 6 5 0
Inactive 6 6
--
Inactive 6 7
--
Inactive 6 8
--
Inactive 6 9
--
* Available only with Clima Manager