EasyManua.ls Logo

Ariston MICROCOMBI 23 MFFI

Ariston MICROCOMBI 23 MFFI
28 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
11
Important! Before any component is removed, the boiler
must be drained of all water.
1.5.1 Removing the pump pressure switch
1.Remove the pump pressure switch electrical connections
W” (F
IG
1.33);
2.Unscrew the pump pressure switch by
using
a spanner on
the nut;
3.Remove the pump pressure switch.
1.5 ACCESS TO THE WATER CIRCUIT
FIG. 1.30
FIG. 1.31
FIG. 1.32
FIG. 1.33
U
V
V
1.4.3 Removing the gas valve
Important! Before removing the gas valve, ensure the gas
supply is turned off.
1. Disconnect all the cables from the solenoid and
modureg;
2. Remove the spark generator (see previous section);
3. Release the nuts “U” (FIG. 1.30);
4. Remove the screws “V” from the bottom of the gas valve
(FIG. 1.31);
5. Remove the gas valve (FIG. 1.32).
W