TECHNICAL INFORMATION
5
GENERAL DATA
Heating input max-min
Heating output max-min
Efficiency at Maximum Thermal Capacity (see
installation instructions)
CENTRAL HEATING
Operating Temperature max-min
Maximum-Minimum Heating Pressure
Built-in expansion vessel - Total capacity
DOMESTIC HOT WATER
Maximum-Minimum Temperature of
Water for Domestic Use
Working pressure max-min
Flow rate T 25°C
Flow rate T 35°C
Minimum flow rate
ELECTRICAL DATA
Electrical Supply/ Frequency
Power Consumption
Protection of Electrical System
CATEGORY
Nominal Pressure/Methane Gas (G20-G25)
Nominal Pressure/Liquid Gas (G30-G31)
kW
kW
%
°C
bar
litres
°C
bar
l/min
l/min
l/min
V/Hz
W
IP
mbar
mbar
25.6-11.0
23.8-9.7
92.9
82-42
3-0.7
6
56-36
8-0.2
13.6
9.7
2.6
230/50
140
X4D
20-25
30-37
23 kW
29.8-12.0
27.8-10.5
93.5
82-42
3-0.7
6
56-36
8-0.2
?
?
2.6
230/50
155
X4D
20-25
30-37
27 kW

Table of Contents