P/N 466-5570 (EN) • REV E • ISS 22MAR22 11 / 18
Door groups
128
Floors
64
Floor groups
128
Maximum user number (with door controllers connected):
CDC4(-EN)
65532
ATS125x without IUM
2000
ATS1250 with ATS1831 IUM
17488
ATS1250 with ATS1832 IUM
65532
Note: SMS and voice reporting features are only available for a limited
user number. Maximum number of users with full control and reporting
functionality is given in General featureson page 10.
Audio features
Maximum audio device
number
8
16
32
UltraSync features
Maximum number of push
notifications
16
Ethernet connection (IP only)
Supported standard
IEEE 802.3u
Speed
10BASE-T or 100BASE-TX
Duplex
Half-duplex and full-duplex
Cabling
FTP (foiled twisted pair) Cat 5e cable
or better
Autonegotiation
MDIX
Standard onboard outputs
S1, S2, S3
High current electronic output, rating:
1 A at 13.8 V
S4, S5 [1]
Low current electronic output, rating:
50 mA at 13.8 V
[1] Maximum cable length for low current output connection may not
exceed 30 m. For longer distances, use relay output expansion
(for example, ATS624 four-relay expander).
Environmental
Operating temperature
0 to +40°C
Tested temperature according
EN 50131
−10 to +55°C
Humidity
95% noncondensing
IP protection grade
IP31
Colour
Beige
Dimensions
See “List of panel variantson page 5
EN 50131 grade and class
ATS1500A(-IP): Grade 2, Class II
ATS3500A(-IP): Grade 3, Class II
ATS4500A-IP: Grade 3, Class II
Note: ATS1500A(-IP)-MM can be
upgraded to an EN Grade 3 setup with
the use of the ATS-MM-TK tamper kit.
Safety class
Class I
Enclosure type
Enclosure (meets UL94V-0)
Earthing cable types
Aritech 160558999-1
Overvoltage category
Category II
Maximum altitude, or minimum
air pressure
2000 m above mean sea level
Fuses
Battery
ATS1500A(-IP), ATS3500A(-IP): 2 A,
resettable
ATS4500A(-IP): 3 A, resettable
12 V aux
1 A, resettable
System databus
1 A, resettable
Siren 1, high current output S1
1 A, resettable
Siren 2, high current output S2
1 A, resettable
Siren 3, high current output S3
1 A, resettable
Mains, mains fuse
ATS1500A(-IP)-SM/LP: T-160 mA,
230 VAC, slow, Aritech 33-119
ATS1500A(-IP)-MM, ATS3500A(-IP),
ATS4500A-IP: T-315 mA, 230 VAC,
slow, Aritech 33-118
Note: Mains fuse is part of the Aritech 120494888 mains terminal block.
WARNING: Before removing the mains fuse, mains power
must be disconnected (see “Mains power connectionon page
6).
Auxiliary current and battery capacity
Table 2: ATS1500A(-IP) maximum available auxiliary current
Battery capacity, Ah
7.2
12
18
Applicable housing
SM,
MM, LP
LP
MM
Security approval /
Grade
Discharge
time, h
Charge
time, h
Auxiliary current, mA
EN Grade 2
12
72
450
750
750
INCERT Grade 2
24
48
150
350
570
INCERT Grade 3
60
24
150
EN Grade 3, VdS-B
30
24
90
250
350
NF&A2P Grade 2
(EN+RTC)
36
72
180
350
NF&A2P Grade 3
(EN+RTC), VdS-C
60
24
150
Table 3: ATS3500A(-IP) maximal available auxiliary current
Battery capacity, Ah
7.2
12
18
Applicable housing
MM, LP
LP
MM
Security approval /
Grade
Discharge
time, h
Charge
time, h
Auxiliary current, mA
EN Grade 2
12
72
450
850
1350
INCERT Grade 2
24
48
150
350
600
INCERT Grade 3
60
24
150
EN Grade 3, VdS-B
30
24
90
250
450
NF&A2P Grade 2
(EN+RTC)
36
72
180
350
NF&A2P Grade 3
(EN+RTC), VdS-C
60
24
150
Table 4: ATS4500A-IP maximal available auxiliary current
Battery capacity, Ah
12
18
25
36
Applicable housing
LM
MM+,
LM
LM
LM
Security
approval / Grade
Discharge
time, h
Charge
time, h
Auxiliary current, mA
EN Grade 2
12
72
850
1350
1600
1600
INCERT Grade 2
24
48
350
600
890
1350
INCERT Grade 3
60
24
150
260
450
EN Grade 3, VdS-
B
30
24
250
450
675
1000