EN 50131 Grade 3 certified components
The Advisor Advanced EN 50131 Grade 3 system exists out
the following components.
Intrusion control panels
• ATS1500A(-IP). Note: ATS1500A(-IP)-MM is upgradable
to Security Grade 3 using the ATS-MM-TK tamper kit.
• ATS3500A(-IP)
• ATS4500A-IP
Keypads / readers (RAS, remote arming station)
Panel can support up to 8 or 16 RAS devices at the same time,
depending on intrusion panel, regardless of type (independent
of other expanders).
• ATS1135: LCD keypad
• ATS1190/1192: Smart Card reader
• ATS1151/ATS1156: Keypad
• ATS1136: LCD keypad
• ATS118x: Smart Card reader series
Remote expanders (DGP, data gathering panel)
Panel can support up to 7 or 15 DGP devices, depending on
intrusion panel, regardless of type (independent of other
expanders).
• ATS1201E: 8 to 32 zone DGP expander with 3 A PSU,
small enclosure, EN 50131 Grade 3
• ATS1204E: 8 to 32 zone DGP expander with 3 A PSU,
large enclosure, EN 50131 Grade 3
I/O expanders
Panel can support up to 3 I/O devices depending on the type.
• ATS608: Plug in 8-zone expander
• ATS624: 4 relay board
• ATS626: 16 open collector output board
Reporting devices
Panel can support 1 GSM device connected onto MI bus.
• ATS7310: GSM communication device
• ATS7320: GSM communication device
• ATS7440: IP/GPRS alarm dialer
• ATS7700: PSTN interface board
When any option, any additional function or any additional
zone type in this section does not comply with the EN 50131
requirements, the EN 50131 Grade 3 label must be removed
from the system. See also “EN 50131 compliance precautions”
below.
EN 50131 compliance precautions
Installation
In order to install an EN 50131 compliant system, please make
sure that all system components are EN 50131 compliant. See
“EN 50131 Grade 3 certified components” above for more
details.
Programming
Make sure that all system settings are in line with regulatory
compliance guidelines. See “EN 50131 Grade 3” on page 13
for more details.
Size of log / event history
For full EN 50131 Grade 3 compliance, the system must store
at least 500 events.
Marking
It is only allowed to mark the system with the EN 50131
Grade 3 label, if the following requirements are met:
• All system components are EN 50131 compliant. Refer to
“EN 50131 Grade 3 certified components” above.
• All settings are done according to “EN 50131 Grade 3” on
page 13.
If any of these two items is not valid, the EN 50131 Grade 3
label must be removed from the system.