EasyManua.ls Logo

ARRI cforce mini RF - Motor Preparation and Mounting; Mounting Procedures

ARRI cforce mini RF
39 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Motor preparation 19
6 Motor preparation
Mounting to 19 mm rods
1. Open the clamp console by turning the thumbscrew counterclockwise.
2. Remove the 19/15mm clamp insert.
3. Attach the clamp console on the rod, with the motor gear engaged to
the lens barrel.
4. Close the clamp console by turning the thumbscrew clockwise.
Mounting to 15 mm rods
1. Open the clamp console by turning the thumbscrew counterclockwise.
2. Attach the 19/15mm clamp insert (K2.0006175) on the 15 mm rod.
3. Attach the clamp console around the clamp insert on the rod, with the
motor gear at the respective lens barrel.
4. Close the clamp console by turning the thumbscrew clockwise.
Note: For high torque applications use CLM-4 Clamp insert
(K2.0002080, not included)
Mounting to Panavision rods
1. Open the clamp console by turning the thumbscrew counterclockwise.
2. Remove the 19/15mm clamp insert.

Related product manuals