Error messages
35
E.013
Calibration data of controller
faulty or EEPROM error.
WARNING: Loss of calibration data. This error can only be fixed by re-calibrating the con-
troller.
Please contact the ARRI service.
E.014 Watchdog error Notice: The product can be used on. This message is more a notification than an error.
E.015 LED channel faulty Notice: The product can be used on. This message is more a notification than an error.
E.016 Battery voltage protection active The battery input detected an input voltage higher than 44 V=.
E.017 Low battery shut off
The output voltage of the battery pack is lower than 23 V=. Change the battery pack. The
product will not react to commands until you disconnect it from the power source.