Supported IPMI Commands
ATCA-7480 Installation and Use (6806800T17A)
232
8.1.6 Sensor Device Commands
Table 8-6 Supported Sensor Device Commands
Command
NetFn
(Request/Response) CMD Comments
Get Device SDR Info 0x04/0x05 0x20 -
Get Device SDR 0x04/0x05 0x21 -
Reserve Device SDR Repository 0x04/0x05 0x22 -
Get Sensor Reading Factors 0x04/0x05 0x23 -
Set Sensor Hysteresis 0x04/0x05 0x24 -
Get Sensor Hysteresis 0x04/0x05 0x25 -
Set Sensor Threshold 0x04/0x05 0x26 Most of the threshold-based
sensors have fixed thresholds.
Before using this command,
check whether threshold
setting is supported by using
the Get Device SDR command.
Get Sensor Threshold 0x04/0x05 0x27 -
Set Sensor Event Enable 0x04/0x05 0x28 -
Get Sensor Event Enable 0x04/0x05 0x29 -
Get Sensor Event Status 0x04/0x05 0x2B -
Get Sensor Reading 0x04/0x05 0x2D -
Get Sensor Type 0x04/0x05 0x2F -
Set Event Receiver 0x04/0x05 0x00 -
Get Event Receiver 0x04/0x05 0x01 -
Platform Event 0x04/0x05 0x02 -