Supported IPMI Commands
ATCA-7480 Installation and Use (6806800T17A)
263
8.4.2 Get Serial Interface Properties Command
The Get Serial Interface Properties command is used to get the properties of a particular serial
interface.
Table 8-30 Get Serial Interface Properties Command Description
Type Byte Data Field
Request Data 1:3 PPS IANA Private Enterprise ID
0x00400A = 16394 (Pigeon Point Systems)
LSB Byte first: byte 1 = 0A, byte 2 = 40, byte 3 = 00
4 Interface ID
0: Serial Debug Interface
Response Data 1 Completion Code
2:4 PPS IANA Private Enterprise ID
0x00400A = 16394 (Pigeon Point Systems)
LSB Byte first: byte 2 = 0A, byte 3 = 40, byte 4 = 00
5 Bit [7] Echo On
If this bit is set, the IPMC enables echo for the given serial
interface.
Bits [6:4] Reserved
Bits [3:0] Baud Rate ID
The baud rate ID defines the interface baud rate as follows:
0: 9600 bps
1: 19200 bps
2: 38400 bps
3: 57600 bps (unsupported)
4: 115200 bps (unsupported)