Supported IPMI Commands
ATCA-7480 Installation and Use (6806800T17A)
258
8.4 Pigeon Point Specific Commands
The IPMC supports additional IPMI commands that are specific to Pigeon Point. This section
provides detailed description of those extensions:
Response Data 1 Completion Code. Generic plus the following command-
specific completion codes:
80h = feature selector not supported.
2 LSB of Artesyn IANA Enterprise Number. A value of CDh shall be
used.
3 2nd byte of Artesyn IANA Enterprise Number. A value of 65h
shall be used.
4 MSB of Artesyn IANA Enterprise Number. A value of 00h shall
be used.
5 Feature Configuration.
Bit [7-0]: Feature Selector = E0h, E1h
00h = disabled
01h = enabled
02h - 0ffh = reserved
Bit [7-0] Feature Selector = 03h:
00h-FFh: Debounce timer timeout value in 100 ms
6 Persistency / Duration
Table 8-26 Get Feature Configuration Command (continued)
Byte Data Field
Table 8-27 Pigeon Point Extension Commands
Command
NetFn
(Request/Response) CMD
Get Status Table 8-29 on page 260 0x2E/0x2F 0x00
Get Serial Interface Properties Table 8-30 on page 263 0x2E/0x2F 0x01
Set Serial Interface Properties Table 8-31 on page 264 0x2E/0x2F 0x02
Get Debug Level Table 8-32 on page 265 0x2E/0x2F 0x03
Set Debug Level Table 8-33 on page 266 0x2E/0x2F 0x04