Connectors
Jumper points and push buttons
Switches
Module key and Backup battery
LEDs
J2 Connector for the Compact Flash
J5 Connection of supply voltage
J6 For connection of RS422 communication
J7 Modular jack (RJ45) for connection of RS232 communication. RS232:3
J8 Modular jack (RJ45) for connection of RS232 communication. RS232:2
J9, J10 LON/GP Interface Connector
J11 Modular jack (RJ45) for connection of RS232 communication. RS232:1
J12, J13 Modular jacks (RJ45) for connection of System 900 bus cabling
J14 Connector where an error relay output is available.
J16 Connects AUX Input and AUX Output
J20 For connection of 10baseT or 100baseT Ethernet TCP/IP network
J22 For internal use only
J24 For connection of A or B-bus from System 900 when modular system bus
cable is not used.
J1 Jumper that activates the backup battery. (Jumper pin 2-3 to activate).
J4 For grounding and production test
J15 Jumper that determines if the Error relay output should be active when
the relay operates or is released. Normally set to 1-2 to select operating.
S1, S2 Jumper points for selection of A or B-bus
S3 For internal use only
S4, S5 Jumper points used when ELISE2 controls the communication on the
A/B-bus.
SW4 Reset button for CPU
SW2 Module address selector switch for A or B-bus. If the setting of SW2 is
changed, the ELISE2 module detects this automatically and will reconnect
to the System 900 with the new address (it takes approximately 30 s).
SW3 Selector switch for operating mode
IC1 CPU
IC2 On-board flash
IC24 Module key
BAT1 Backup battery
LED1 Function indicator with green, orange and red indication
LED2-LED5 Application dependent functionality. See documentation on the
application for description.
LED6 Communication on the Ethernet
LED7 Ethernet speed indicator. ON 100 Mbit/s, OFF 10 Mbit/s