REGULATING THE BURNER MINIMUM SETTING
When switching from one type of gas to another,the minimum
flow rate must also be correct:the flame should not go out even
when passing suddenly from maximum to minimum flame. To
regulate the flame follow the instructions below:
√Light the burner
√Set the cock valve to minimum
On gas valves provided with adjustment screw in the centre
of the shaft(fig.21)
√Using a screwdriver with max.diameter 3 mm,turn the screw
inside the tap until the correct setting is obtained.
On gas valves provided with adjustmet screw on the valve
body(fig.22):
√turn the screw “A” to the correct setting with a screwdriver.
Normally for G30 gas, fully tighten the adjustment screw.
LUBRICATION OF THE GAS TAPS
If the gas tap becomes stiff, it is necessary to dismount it
accurately clean it with gasoline and spread a bit of special
grease resistant to high temperatures on it.
The operations must be executed by a qualified technician.
ELECTRICAL SECTION
IMPORTANT:
Installation has to be carried out according to instructions
provided by the manufacturer.