28
Command Class Configuration, Version 4*
* This command class requires security.
Table 8 - Configurable Parameters
Param.
Num.
Name
Length
Configuration Properties
Info
Length of
Info
String
Min
Max
Default
(Max
length
allowed
is 90)
1
Volume
1 byte
0x01 (High
Volume)
0x03 (Silent)
0x02 (Low
Volume)
[0x8002,
0x8109,
0x8103 &
0x8113]
Set Volume Level to
high (1), low (2), or
silent (3). [0x8002,
0x8109, 0x8103,
0x8104 & 0x8113]
53
0x01 (High
Volume)
[0x810A,
0x8004 &
0x8104]
Set Volume Level to
high (1) or silent
(3). [0x810A &
0x8004]
44
2
Auto Relock
1 byte
0x00 (Disable)
0xFF (Enable)
0x00
(Disable)
Set Auto Relock
feature to enable or
disable.
45