Questions and Answers

  • P
    phillipsrobertSep 1, 2025
    What does 'low ambient temperature protection' mean for my Astralpool PROELYXP16i?
    • W
      William HowellSep 1, 2025
      The 'low ambient temperature protection' message on your Astralpool Heat Pump indicates that the unit is either being used outside of its intended environment or that there is a sensor abnormality. Stop using the unit if it is beyond its operating scope, or change the sensor.
  • L
    Lucas MyersSep 2, 2025
    What causes piping temperature too high protection under cooling mode T3 in Astralpool PROELYXP16i?
    • U
      ubryantSep 2, 2025
      Piping temperature too high protection under cooling mode T3 in your Astralpool Heat Pump can be caused by a high ambient or water temperature, or an abnormal refrigeration system. Check the scope of using and the refrigeration system.
  • C
    Chad WalshSep 3, 2025
    What to do if my Astralpool PROELYXP16i displays IPM module protection?
    • K
      Kathy RichardsSep 3, 2025
      If your Astralpool Heat Pump displays an IPM module protection error, it could be due to a data mistake, wrong compressor phase connection, compressor liquid and oil accumulation, or a damaged compressor or driver board. You can try turning off the electricity supply and restarting after 3 minutes, changing the driver board, or checking the compressor sequence connection.
  • A
    Amanda Freeman DDSSep 3, 2025
    What does 'VDC voltage too low protection' mean for my Astralpool Heat Pump?
    • K
      Katelyn HickmanSep 4, 2025
      The 'VDC voltage too low protection' error in your Astralpool Heat Pump indicates that the line voltage is too low or the driver board is damaged. Check if the power is in the normal range or change the driver board.
  • A
    amberrileySep 4, 2025
    What causes input current over high protection in my Astralpool PROELYXP16i?
    • X
      Xavier WatsonSep 5, 2025
      Input current over high protection in your Astralpool Heat Pump can be caused by a large momentary compressor current, abnormal water flow, power fluctuations, or an incorrect PFC inductor. Try checking the compressor, the waterway system, the power range, and if the correct PFC inductor is used.
  • T
    tcarlsonSep 5, 2025
    How to troubleshoot IPM module thermal circuit abnormality in Astralpool PROELYXP16i?
    • L
      laurarobertsSep 5, 2025
      An abnormal IPM module thermal circuit in your Astralpool Heat Pump can be caused by an output abnormality of the IPM module thermal circuit or a problem with the fan motor (abnormal or damaged) or a broken fan blade. Try changing the driver board, checking if the motor speed is too low or fan motor is damaged, or changing the fan blade.
  • V
    Vincent AlvarezSep 6, 2025
    What to do if my Astralpool PROELYXP16i shows IPM module temperature too high protection?
    • J
      Jessica McculloughSep 6, 2025
      If your Astralpool Heat Pump displays an IPM module temperature too high protection error, it could be due to an output exception of the IPM module thermal circuit, an abnormal or damaged motor, or a broken fan blade. Try changing the driver board, checking if the fan motor speed is too low or fan motor is damaged, or changing the fan blade.

Summary

Description

1.1 Included with your Heat Pump

Lists all included accessories with the heat pump.

Specifications

Technical Data Overview

Comprehensive technical specifications for the PRO ELYO INVERBOOST NN series.

Location and Connection

5.1 Heat Pump Location

Guidelines for choosing an optimal installation site for the heat pump.

5.4 Initial Operation

Procedure for starting and operating the heat pump for the first time.

Electrical Wiring

6.1 Inverter Swimming Pool Heat Pump Wiring Diagram

Wiring diagram for models 71676/71677/71678/71679/71680.

6.3 Inverter Swimming Pool Heat Pump Wiring Diagram

Wiring diagram for models 71682/71683.

6.4 Inverter Swimming Pool Heat Pump Wiring Diagram

Wiring diagram for model 68822 (R410A).

6.5 Inverter Swimming Pool Heat Pump Wiring Diagram

Wiring diagram for models 68821/68823 (R410A).

6.6 Electrical Connection

Requirements and guidelines for safe and proper electrical hookup.

Start-up of the Heat Pump

7.3 Heating Operation Logic

Logic and conditions governing the heat pump's heating cycles.

7.4 Cooling Operation Logic

Logic and conditions governing the heat pump's cooling cycles.

Troubleshooting

8.1 Error Code Display

Guide to interpreting error codes shown on the LED controller.

8.2 Other Malfunctions and Solutions

Troubleshooting for issues not indicated by error codes.

Astralpool PROELYXP16i Specifications

General IconGeneral
BrandAstralpool
ModelPROELYXP16i
CategoryHeat Pump
LanguageEnglish

Related product manuals