MC4111L / MAG 690
Technische documentatie
19 - CONTROLS ON POWER CARD
Control:
Ø Between X100 (L) and X101 (N) = 230 Volts.
Between X100 and PAD100 (earth) = 230 Volts, if not, disconnect the oven and invert the pods on X100
and X101 to refer the neutral on the components low tension.
20 - THE "DEMO" MODE
The demo mode is saved even in event of power cut.
it is saved in E2PROM
Ø Activation
• Set the clock to 00H00
• Press at the same time, the three keys, located on
the left keyboard, during a minimum of 5 seconds (Validation by a long “beep”).
• The word "Demo" appear 1 second every 8 seconds.
Ø Cancellation
• Set the clock to 00H00
• Press at the same time, on the three keys, located
on the left keyboard, for cancellation a minimum of
5 seconds (Validation by a long “beep”).
• "DEMO" disappears.