MC4111L / MAG 690
Technische documentatie
1.4. - Electric connection
Before connecting of the appliance, check that it has not been damaged during the transport (Door or
deformed seal).
Check that :
The electrical installation has sufficient voltage.
The supply cables are in good condition.
The diameter of the wires complies with the installation requirements.
The installation must be protected with a fuse 16 A.
The responsibility for the manufacturer could not be committed in the event of consecutive accident
with an ground electrical non-existent or incorrect.
Electrical safety must be ensured through proper installation in the housing. During installation and
maintenance operations, the appliance must be unplugged from the electrical grid ; fuses be cut off or
removed.
This plug must be easily accessible after installation.
The appliance must be connected using a (standardised) feeder cable with 3 conductors of 1,5 mm
2
(1 Live + 1 neutral + ground) which must be connected to the 220-240 V ~ monophase network using a
CEI 60083 standardised 1 Live + 1 neutral + ground electrical outlet or one which complies with
installation requirements. The protection cable (green-yellow) is connected to the appliance’s ground
terminal and must be connected to the appliance’s ground.