Model Working pressure (psi) Supply voltage (V) Q40 (A)
GA 132 VSD+ 125 440 12
GA 132 VSD+ 150 440 12
GA 132 VSD+ 125 460 12
GA 132 VSD+ 150 460 12
GA 160 VSD+ 125 380 12
GA 160 VSD+ 150 380 12
GA 160 VSD+ 125 440 12
GA 160 VSD+ 150 440 12
GA 160 VSD+ 125 460 12
GA 160 VSD+ 150 460 12
Maximum customer fuse setting
Model Supply voltage (V) Electrical approval Field circuit
protection (A)
Type, field circuit
protection
GA 110 VSD+ 380 IEC 3x550 aR
GA 110 VSD+ 400 IEC 3x550 aR
GA 110 VSD+ 440 IEC 3x550 aR
GA 110 VSD+ 460 CSA-UL 3x550 Bussmann 170M
GA 110 VSD+ 525 IEC 3x550 aR
GA 110 VSD+ 575 CSA-UL 3x550 Bussmann 170M
Instruction book
120 9829 3178 63
GA 132 VSD+ 380 IEC 3x550 aR
GA 132 VSD+ 400 IEC 3x550 aR
GA 132 VSD+ 440 IEC 3x550 aR
GA 132 VSD+ 460 CSA-UL 3x550 Bussmann 170M
GA 132 VSD+ 525 IEC 3x550 aR
GA 132 VSD+ 575 CSA-UL 3x550 Bussmann 170M
GA 160 VSD+ 380 IEC 3x630 aR
GA 160 VSD+ 400 IEC 3x630 aR
GA 160 VSD+ 440 IEC 3x630 aR
GA 160 VSD+ 460 CSA-UL 3x630 Bussmann 170M
GA 160 VSD+ 525 IEC 3x550 aR
GA 160 VSD+ 575 CSA-UL 3x550 Bussmann 170M