10 Technical data
10.1 Readings on display
Important
The readings are valid when operating under reference conditions. See the
section Reference conditions.
Normally the main display is shown, indicating the actual air outlet pressure and
the actual compressor status. The arrow down key allows the operator to call up
other information such as actually measured pressures and temperatures.
Important readings
Compressor outlet pressure bar(e) (psig) Depends on running speed
and working pressure
Pressure drop over air filters bar Below 0.05
Pressure drop over air filters psi Below 0.73
Pressure difference over oil separator bar Below 0.8
Pressure difference over oil separator psi Below 12
Oil injection pressure at the compressor elements bar(e) (psig) Depends on working
pressures
Compressor outlet temperature, air-cooled Pack compressors ˚C Approx. 28
Compressor outlet temperature, air-cooled Pack compressors ˚F Approx. 82
Compressor outlet temperature, air-cooled Full-Feature
compressors
˚C Approx. 25
Compressor outlet temperature, air-cooled Full-Feature
compressors
˚F Approx. 77
Compressor outlet temperature, water-cooled compressors ˚C Approx. 22
Compressor outlet temperature, water-cooled compressors ˚F Approx. 72
Cooling air inlet temperature of Pack compressor ˚C Below 46
Cooling air inlet temperature of Pack compressor ˚F Below 115
Cooling air inlet temperature of Full-Feature compressor ˚C Below 46
Cooling air inlet temperature of Full-Feature compressor ˚F Below 115
Cooling air inlet temperature of Pack compressor (high
ambient temperature variant)
˚C Below 50
Cooling air inlet temperature of Pack compressor (high
ambient temperature variant)
˚F Below 122
Cooling water temperature ˚C Below 50
Cooling water temperature ˚F Below 122
Pressure dew-point ˚C Approx. 3
Pressure dew-point ˚F Approx. 37
Instruction book