5.3 Starting
Warning
The operator must apply all relevant Safety precautions.
On Full-Feature compressors, switch on the voltage 4 hours before starting in order to
energize the crankcase heater of the refrigerant compressor.
Control panel
Reference Designation Function
1 Touchscreen Shows the compressor operating condition and a
number of icons to navigate through the menu.
The screen can be operated by touch.
2 Warning sign Flashes in case of a shut-down, is lit in case of a
warning condition.
3 Service sign Is lit when service is needed.
4 Operation sign Is lit when the compressor is running in automatic
operation.
5 Voltage sign Indicates that the voltage is switched on.
6 Stop button This button stops the compressor.
7 Start button This button starts the compressor. The operation
sign (4) lights up. The controller is operative.