Control panel
Reference Designation Function
1 Touchscreen Shows the compressor operating condition and a
number of icons to navigate through the menu.
The screen can be operated by touch.
2 Warning sign Flashes in case of a shut-down, is lit in case of a
warning condition.
3 Service sign Is lit when service is needed.
4 Operation sign Is lit when the compressor is running in automatic
operation.
5 Voltage sign Indicates that the voltage is switched on.
6 Stop button This button stops the compressor.
7 Start button This button starts the compressor. The operation
sign (4) lights up. The controller is operative.
Procedure
Step Action
1 Switch on the voltage. The voltage sign (5) lights up.
2 Close the condensate drain valves.
3 Open the air outlet valve.
4 Check the oil sight-glass. Minimum level should reach the oil sight-glass when the
compressor is stopped.
5 Open the water shut-off valves and the water regulating valve.
Instruction book
80 9829 3178 63