Ambient temperature Humid Dust Duty type
Between 30 °C (86 °F)and 40 °C (104 °F) Yes No Demanding
Between 30 °C (86 °F) and 40 °C (104 °F) No Yes Demanding
Between 30 °C (86 °F) and 40 °C (104 °F) Yes Yes Extreme
Above 40 °C (104 °F) - - Extreme
Exchange interval for Roto-Inject Fluid Ndurance
Ambient temperature Element outlet
temperature
Exchange interval * Maximum time interval
*
up to 30°C (86°F) up to 95°C (203°F) 4000 1 year
from 30°C (86°F) up to
35°C (95°F) (see note)
from 95°C (203°F) up to
100°C (212°F)
3000 1 year
from 35°C (95°F) up to
40°C (104°F) (see note)
from 100°C (212°F) up to
105°C (221°F)
2000 1 year
above 40°C (104°F) above 105°C (221°F) use Roto Synthetic Fluid Xtend Duty
Note: the presence of dust and/or high humidity may require a shorter exchange interval. Consult
Atlas Copco.
Exchange interval for Roto Synthetic Fluid Ultra
Ambient temperature Element outlet
temperature
Exchange interval * Maximum time interval
*
up to 35°C (95°F) up to 100°C (212°F) 6000 2 years
from 35°C (95°F) up to
40°C (104°F) (see note)
from 100°C (212°F) up to
105°C (221°F)
4000 2 years
from 40°C (104°F) up to
45°C (113°F) (see note)
from 105°C (221°F) up to
110°C (230°F)
2000 2 years
Exchange interval for Roto Synthetic Fluid Xtend-Duty
Ambient temperature Element outlet
temperature
Exchange interval * Maximum time interval
*
up to 35°C (95°F) up to 100°C (212°F) 8000 2 years
from 35°C (95°F) up to
40°C (104°F) (see note)
from 100°C (212°F) up to
105°C (221°F)
6000 2 years
above 40°C (104°F) above 105°C (221°F) 5000 2 years
Note: the presence of dust and/or high humidity may require a shorter exchange interval. Consult