MT Focus 400 EN Installation
© Atlas Copco Industrial Technique AB - 9836 6294 01
11
PNP mode
I/O Description
INT -24V +24 V output
EXT-OUT-COM0 Connect to INT +24V
or external +24 V
(not at the same time)
EXT-OUT0...EXT- OUT3 The outputs will be connected to the external +24 V
when activated.
EXT-IN0...EXT- IN3 The inputs will be activated by a +24 V signal applied
to the input pin.
EXT-IN-COM0 Connect to DGND
or external 0 V.
DGND 0 V output
NPN mode
I/O Description
INT -24V +24 V output
EXT-OUT-COM0 Connect to DGND
or external 0 V.
EXT-OUT0...EXT- OUT3 The outputs will be connected to the external 0 V
when activated.
EXT-IN0...EXT- IN3 The inputs will be activated by a 0 V signal applied to
the input pin.