EasyManua.ls Logo

Atlas Copco MT Focus 400 - Configurable Digital I;O

Atlas Copco MT Focus 400
28 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Installation EN MT Focus 400
10
© Atlas Copco Industrial Technique AB - 9836 6294 01
Configurable digital inputs and outputs (DIGITAL I/O)
15-pole D-sub socket connector for configurable signals.
Use a 15-pole D-sub pin plug.
Voltage range 11-30 VDC
Input resistance >5 kΩ
Output resistance 23-35 Ω
Output current protection 120 mA max. peak/continuous current, over current
protected.
Input response time <25 ms (with de-bouncing filter)
Output response time <5 ms
NOTICE
If the max. current is exceeded, the output voltage will switch off. This can be resolved by switch-
ing the output off and on again.
Pin I/O Description Default
1 INT 24V Internal 24 V supply
2 EXT-OUT-COM0 External common line for
outputs
3 EXT-OUT0 Configurable Busy
4 EXT-OUT1 Configurable Tightening OK
5 EXT-OUT2 Configurable Tightening NOK
6 EXT-OUT3 Configurable Batch OK
7 Not used
8 EXT-IN0 Configurable Start tightening
9 EXT-IN1 Configurable Reset tool
10 EXT-IN2 Configurable Start loosening
11 EXT-IN3 Configurable Reset batch
12 Not used
13 Not used
14 EXT-IN-COM0 External common line for
inputs
15 DGND Internal ground
For information on configuration on the outputs and inputs, see ToolsTalk MT - Reference - I/O status.
NOTICE
All inputs are opto isolated.
If used to reset the tool, the signal duration must be more than 40 ms.
Interface connection can be connected in PNP mode (source type, positive logic), or in NPN
mode (sink type, negative logic).