MT Focus 400 EN Installation
© Atlas Copco Industrial Technique AB - 9836 6294 01
9
Pin Signal Description
1 TxD Transmitted data
2 GND Data ground
3 RxD Received data
Vacuum pump output (VP)
5-pole socket connector for the connection of Atlas Copco Vacuum pump VPX6 (24 V, 600 mA).
Use a 5-pole pin plug from the Binder 719 Series.
Pin Output Description Default
1 +24 V Internal +24 V
2 +24 V Internal +24 V
3 Pump on Digital output
4 GND (0 V) Internal 0 V
5 GND (0 V) Internal 0 V
Configurable single input (I/O)
5-pole pin connector, configurable, e.g. as input for foot switch.
For information on configuration of the input, see ToolsTalk MT - Reference - I/O status.
Use a 5-pole socket plug from the Binder 719 Series.
NOTICE
■
This input is not opto-isolated.
Input resistance 10 kΩ
NOTICE
■
If used to reset the tool, the signal duration must be more than 40 ms.
Pin Output Description Default
1 +24 V Internal +24 V
2 GND (0 V) 0 V output
3
4
5 Digital in Digital input Start tightening
A 2 wire switch (e.g. a reed switch) is connected to pin 1 and 5.
A sensor with PNP output is connected to pin 1, 2 and 5.