Auto-set
1. Press either the UP or the DOWN button
2. Select Autoset in the menu.
3. Press OK.
4. If required, enter the password. Use the OK button to select a position and the UP or the DOWN but-
tons to select the number.
5. Set the required tightening torque. Use the UP or the DOWN buttons to set the torque.
6. Press OK.
7. Check that the correct PSet is shown. If so, select yes and press OK.
If not, return by selecting no and pressing OK.
8. Perform three tightenings.
NOTICE
■
Each tightening should be done using a new joint.
9. If tightenings are not successful, repeat the tightening. if all tightenings are successful, Auto-set
done is shown.
10. If the speed is to be changed, press the DOWN button and use the UP or the DOWN buttons to set
the speed. Press OK to continue.
11. If the min. angle is to be changed, use the UP or the DOWN buttons to set the min. angle. Press OK
to continue.
12. If max. angle is to be changed, use the UP or the DOWN buttons to set the max. angle. Press OK to
continue.
13. If the trigger torque for angle counting is to be changed, use the UP or the DOWN buttons to set the
trigger torque for angle counting. Press OK to continue.
14. In order to revise the settings, repeat steps 10-13.
15. Press OK to finish.
Select program set (PSet)
1. Press either the UP or the DOWN button
2. Select Select PSet in the menu.
3. Press OK.
4. If required, enter the password. Use the OK button to select a position and the UP or the DOWN but-
tons to select the number.
5. Select the required program set.
6. Press OK.