38
ORV 10 - ORV 12 - ORX 10 - ORX 12
10. LEGISLATION
10.1 PARTS, SUBJECTED TO PRESSURE EQUIPMENT DIRECTIVE 97/23/EC, CAT. II AND ABOVE
Safety valve: cat. IV
10.2 PARTS, SUBJECTED TO SIMPLE PRESSURE VESSEL DIRECTIVE 87/404/EC
Air Oil separator (ORV)
10.3 PARTS, SUBJECTED TO SIMPLE PRESSURE VESSEL DIRECTIVE 87/404/EC
Air Oil separator (ORX)
10.4 PARTS, SUBJECTED TO CAT. I AND COVERED BY THE MACHINE DIRECTIVE 89/392/EC
All other parts
10.5 PARTS, SUBJECTED TO ART. I, PARAGRAPH 3.3
All other parts
ORV 10
ORV 12
ORX 10
ORX 12
Set pressure bar(e) 30 34
Design temperature °C 130 130
Standard Cold start equipment
Design pressure bar(e) 30 30
Design temperature max. °C 130 130
Design temperature min. °C -10 -25
Volume l 143 143
Standard Cold start equipment
Design pressure bar(e) 34 34
Design temperature max. °C 130 130
Design temperature min. °C -10 -25
Volume l 143 143