Operator’s instructions
3. Daily checks
37
Drill rig
Table: Drill rig.
Hydraulic oil filter
Figure: Hydraulic oil filter and manometer.
Table: Hydraulic oil filter.
Note
The return oil filter pressure gauge (2) is only reliable when the oil has reached a
temperature of at least 40
°
C (104
°
F)
Check point Inspection Instructions
Drill rig Visual check Look for any signs of leaks.
-Hydraulic systems
-Fuel system
-Cooling system
-Compressor
Check point Inspection Instructions
Hydraulic oil filter
(1)
Visual check If the needle on the return oil
filter pressure gauge (2) is in the
red, the filter must be changed.
Call a service technician.
1
2
1250 0316 01

Table of Contents