Operator’s instructions
5. Operating
54
2. Set the switch for Compressor charging/Positioning (13) to position (b) COM-
PRESSOR OFF/POSITIONING REAR CONTROL PANEL.
Figure: Diesel panel
3. Press the Reset button (19).
4. Turn the Ignition key (20) to PREHEATING position (c).
• Preheating lamp (11) and Alarm lamps (9) and (10) are switched on.
5. When the preheating lamp (11) is switched off, turn the ignition key to START
position (d).
1
2
3
4
5
6
7
8
9
10
11
12
13 14 15 16 17 18
a b
a
b
a
b
a
b
c
d
1250 0333 31
a
b
c
a
b
c
19