- 72 -
Glycol concentration measurement
To optimise the unique engine protection features
of the PARCOOL EG the concentration of the
Glycol in the water should be always above
33 vol.%.
Mixtures with more than 68 vol.% mix ratio in
water are not recommended, as this will lead to
high engine operating temperatures.
A refractometer can be ordered from Atlas Copco
with part number 2913 0028 00.
5.4.3.2 Topping up of coolant
Verify if the engine cooling system is in a good
condition (no leaks, clean,...).
Check the condition of the coolant.
If the condition of the coolant is outside the limits,
the complete coolant should be replaced (see
section “Replacing the coolant”).
Always top-up with PARCOOL EG.
Topping up the coolant with water only, changes
the concentration of additives and is therefore not
allowed.
5.4.3.3 Replacing the coolant
Drain
Completely drain the entire cooling system.
Used coolant must be disposed or recycled in
accordance with laws and local regulations.
Flush
Flush twice with clean water. Used coolant must
be disposed or recycled in accordance with laws
and local regulations.
From the Atlas Copco Instruction book, determine
the amount of PARCOOL EG required and pour
into the radiator top tank.
It should be clearly understood that the risk for
contamination is reduced in case of proper
cleaning.
In case a certain content of ‘other’ coolant remains
in the system, the coolant with the lowest
properties influences the quality of the ‘mixed’
coolant.
Fill
To assure proper operation and the release of
trapped air, run the engine until normal engine
operation temperature is reached. Turn off the
engine and allow to cool.
Recheck coolant level and add if necessary.
In case of a mix of different coolant
products this type of measurement
might provide incorrect values.
!