5. The controller (7) will activate the engine
protection systems. If any of the parameters
deviate from the norm (for example, low oil or
fuel level, etc) the controller will intervene and
signal the problem. The manual for the controller
that also accompanies the machine, will provide
you with more information on the error message
displayed.
Switching off the engine
Follow the instructions below to switch the engine off
correctly:
1. Disconnect all electrical appliances connected to
the sockets (1).
2. Place all the automatic switches in their OFF
position (2).
3. It is important to let the engine run at zero load for
a few minutes before turning it off.
4. Turn the key counterclockwise into the OFF
position (3) to switch off the engine
7
Should an emergency arise, it is also
possible to stop the machine by
pressing the EMERGENCY 'STOP'
button (4). If the machine is stopped
in this way, the emergency stop
button must then be released by
rotating it clockwise.