Page #14 background image
www.atlascopco.com
Error
code Description
Ack-
now-
ledge What to do?
Help
text
E403
IO device not
responding
No Check cables and restart drive.
E408
Multiple devices
of same type on
IO bus
Yes You are only allowed to use one.
E409
Multiple selectors
on IO bus
Yes
E410
No selector
found and pset
source is IO bus
Yes
Connect the Selector and restart
the drive or choose None
on Selector Source in TTDS/
Configuration.
E412
IO expander has
ID <> 2
Yes
E413
RE Alarm has ID
<> 3
Yes
E415
4 socket selector
has ID <> 5
Yes
E416
8 socket selector
has ID <> 6
Yes
E501 Tool overheated No Let the tool cool down and restart.
E502 Service Indicator Yes Service the tool.
E517
Tool maxtorque
or Gear Ratio out
of range
Yes Check tool memory.
E601 Dcbus LO Yes
Restart drive. If problem still
remains check line voltage.
E602 Dcbus HI Yes
Restart drive. If problem still
remains check line voltage.
ERROR CODES
9833 1424 01
Åtta.45 Tryckeri AB 2008:
1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Atlas Copco Tensor and is the answer not in the manual?

Atlas Copco Tensor Specifications

General IconGeneral
BrandAtlas Copco
ModelTensor
CategoryDC Drives
LanguageEnglish

Related product manuals