- 39 -
DURING OPERATION
Regularly carry out following checks:
1. That the regulating valve (RV) is correctly
adjusted, i.e. starts decreasing the engine speed
when reaching the preset working pressure in the
receiver.
2. Check the air outlet temperature of the
compressor element.
3. Check the engine oil pressure, the coolant
temperature and all lamps for normal readings.
4. Avoid the engine running out of fuel.
Nevertheless, if this happens, fill the fuel tank and
prime the fuel system to speed up starting (see
section Priming instructions).
OPERATIONS OVERVIEW
It is possible to control the compressor locally with
the Control Box, remotely with the remote switch
inputs located on the back of the Control Box, or with
software running on a PC with a CAN interface (PC
Control Mode).
The way one ends up in each status can differ from
how the Control Box is controlled, but the function of
each status stays the same.
When reading this document, mind the difference
between a status and a procedure. A status is a state in
the Control Box's operation. A procedure is an action
executed by the Control Box.
Example: The Stopping procedure is executed in the
Stopping status, the Start Failure status and the
Shutdown status.
The doors must be closed during
operation and may be opened for short
periods only.