Instruction Manual
102 2954 2510 03
Engine to frame:
Lifting beams to frame:
Hose clamps:
Note
8.2 Compressor / engine specifications
8.2.1 Reference conditions
The inlet conditions are specified at the air inlet grating outside the canopy.
Assemblies Torque value (Nm / lbf.ft)
Bolts, engine/support 205 (151.29)
Bolts, support/buffer 46 (33.95)
Bolts, buffer/frame 23 (16.97)
Assemblies Torque value (Nm / lbf.ft)
Bolts, lifting beams/yoke (M12) 125 (92.25)
Bolts, lifting beams/yoke (M16) 205 (151.29)
Bolts, lifting beams/A-Frames 205 (151.29)
Bolts, A-Frames/frame 205 (151.29)
Assemblies Torque value (Nm / lbf.ft)
Pebra hose clamps on all IC/radiator hoses 12 (8.85)
Secure the drain cock and tank cap of the fuel tank handtight.
Designation XRHS 506 -
XRHS 1100 CD6
XRVS 476 -
XRVS 1000 CD6
Absolute inlet pressure bar(e) 1 1
psi 14.5 14.5
Relative air humidity % - -
Air inlet temperature °C 20 20
°F 68 68
Nominal effective working pressure bar(e) 20 25
psi 290 363