Starting / Stopping
Safety precautions
Make sure the fuel tank is filled up when “INTERNAL
FUEL” is selected.
Battery switch
The compressor is equipped with a battery switch.
When the compressor is not in use this switch must always
be in the “OFF” position.
It is not allowed to use this switch as an emergency switch
or for stopping the compressor. It will cause damage in the
control unit when using this switch for stopping.
Always first shut off the control unit and wait until the
display is dark before switching the battery switch to
position “OFF”.
Control panel
Do not disconnect power supply to control
box in any way when the control box is
switched on. This will cause memory loss.
Do not switch off the circuit breaker when
the control box is switched on. This will
cause memory loss.
Please be aware that the (optional)
preheater unit is still “live” with the battery
switch in “OFF” position.
Reference Name
POWER OFF / ON switch
To switch the control panel on and off
START button
Pressing this button will start the compressor.
STOP button
Pressing this button will stop the compressor in a controlled way.