TOPPING UP WITHOUT DRAINING FROM THE COOLING SYSTEM
The quantity of PARCOOL EG Concentrate to be topped up can be estimated with the following formula and/or graph:
Corrections concentrate in measured system towards 50% volume by using PARCOOL EG Concentrate
Example:
Total volume coolant =
Measured concentration =
In case of expansion tank at low level, this quantity is to
be filled without draining from the cooling system.
1. Refractometer indication -20° C (33%)
2. Refractometer indication -22° C
3. Refractometer indication -25° C
4. Refractometer indication -30° C
5. Refractometer indication -36° C
Liter PARCOOL EG Concentrate
PN: 1604 8159 00
4
0,0
0,5
1,0
1,5
2,0
2,5
3,0
3,5
4,0
4,5
5,0
5,5
6,0
5678910111213141516
1
2
3
4
5
Engine coolant capacity (liter)
Top-up volume PARCOOL EG Concentrate without drainage
Top-up volume (liter)
14 Litre
33 Vol%
50 - 33 = 17 * 14 / 50 = 4,8