EasyManua.ls Logo

Atlas Copco XRVS 1000 CD7 IT4 HOP - Stopping the Compressor; Shutdown and Power Off Procedures; Diesel Particulate Filter Regeneration

Atlas Copco XRVS 1000 CD7 IT4 HOP
88 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
- 39 -
After cooling down the engine will stop and the display
will show
The engine is stopped, and the controller will do a double
check to see if the engine is really stopped.
SHUTDOWN
When the machine is shutdown due to a critical alarm or
an emergency stop the display will show
POWER OFF
Switch the controller off by switching the Power switch to
the position “OFF”.
The compressor is equipped with a battery switch.
When the compressor is not in use, this switch must
always be in the “OFF” position.
It is not allowed to use this switch as an emergency switch
or for stopping the compressor.
It can damage the controller or the engine’s Electronic
Control Unit when using the battery switch for stopping.
Always first shut off the controller and wait until the
display is dark before switching the battery switch to
position “OFF”.Diesel Particulate Filter Regeneration
DIESEL PARTICULATE FILTER REGENERATION
When the Diesel Particle Filter regeneration process is
kept at its default ‘AUTOMATIC’ setting, then the DPF
regeneration will be performed automatically when the
Soot Load exceeds 60%.
The controller display will indicate an ongoing DPF
Regeneration by showing the HEST icon (High Exhaust
System Temperature):
Active Buttons
Start Button
(to initiate Start command)
Measurement View Button
Settings View Button
Alarms View Button
MAIN VIEW
ENGINE STOPPING
--RPM 5.3bar41% 1286h
Active Buttons
Measurement View Button
Settings View Button
Alarms View Button
Enter Button
(to acknowledge the shown alarm)
MAIN VIEW
SHUTDOWN
0.0
2000 EMERGENCY STOP
HEST Icon

Table of Contents