STARTING
Switch on the battery switch.
Switch the controller on by switching the Power switch to
the position “ON”.
The instrument panel will now perform a selftest; the
following display will be shown and the controller is
initialized:
During initializing all buttons/inputs/outputs/alarms are
inactive.
This view will be shown for about 2 seconds, after which
the display will show the Main View.
The actual vessel pressure is shown. If the measured
vessel pressure is higher than 1.5 bar, the unit will not
start. The vessel pressure has to be lowered by opening the
blow down valve. After power up, the vessel pressure
normally is low enough to proceed with the starting
procedure.
The display now shows
The machine is now ready to be started and is waiting for
a start command.
Xc3003
v1.00.0 (r7307)
If the Power switch is turned to the “OFF”
position while the vessel is blowing down, it
will not power down for as long as the vessel
pressure is higher than 1.5 bar.
Active Buttons
Measurement View Button
Settings View Button
Alarms View Button
MAIN VIEW
VESSEL BLOWING DOWN
3.9
1200RPM 3.9bar41% 1286h
Active Buttons
Start Button
(to initiate Start command)
Load Button
(to activate Automatic Load)
Measurement View Button
Settings View Button
Alarms View Button
MAIN VIEW
PREPARING FOR START
0.0
--RPM 0.0bar41% 1286h