Supply voltage
(V)
Recommended overload setting F21
(A)
380 168
440 143
460 137
575 110
ZT/ZR 145 compressors designed for a maximum inlet temperature of 40 ˚C/104 ˚F with IE2 motor
Supply voltage
(V)
Recommended overload setting F21
(A)
380 180.1
440 155.9
460 149.6
575 119.9
ZT/ZR 145 compressors designed for a maximum inlet temperature of 40 ˚C/104 ˚F with IE3 motor
Supply voltage
(V)
Recommended overload setting F21
(A)
380 184
440 156
460 149
575 120
ZT/ZR 145 compressors designed for a maximum inlet temperature of 50 ˚C/122 ˚F with IE2 motor
Supply voltage
(V)
Recommended overload setting F21
(A)
380 172.6
440 149.8
460 140.7
575 112.7
ZT/ZR 145 compressors designed for a maximum inlet temperature of 50 ˚C/122 ˚F with IE3 motor
Supply voltage
(V)
Recommended overload setting F21
(A)
380 168
440 143
460 137
575 110
ZR/ZT 160 compressors designed for a maximum inlet temperature of 40 ˚C/104 ˚F with IE2 motor
Instruction book
2920 1815 04 307