Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not
permitted unless authorised by AUDI AG. AUDI AG does not guarantee or accept any liability
with respect to the correctness of information in this document. Copyright by AUDI AG.
Result: Measure:
Measured value ≥ critical
value
Renew diesel particulate filter and reset measured value to zero ⇒ Engine; Rep.
gr. 26 ; Emission control system; Removing and installing particulate filter .
Note
♦
The critical values listed are always given for one diesel par‐
ticulate filter.
♦
For vehicles with two exhaust pipes, the ash deposit volume
must be read out for both diesel particulate filters.
3.2 Event memory: reading out and erasing
WARNING
Risk of injury as engine of high-voltage vehicle can start un‐
expectedly!
♦ Observe warnings for high-voltage system:
♦ For work that must be performed with the ignition switched
on ⇒ page 11 .
Procedure:
– Connect vehicle diagnostic tester ⇒ page 20 .
– Select Diagnosis mode and begin diagnosis.
– Perform vehicle identification.
– Select “Working with Guided Fault Finding” by entering v and
press Apply
.
The control unit is then identified, and the event memory is inter‐
rogated. Observe notes and test conditions.
– Switch to “Control units” tab and call up “Event memory list”
for an overview of all entries stored in event memory.
– Correct relevant faults and erase event memory.
Note
The event memory is erased automatically if the Guided Fault
Finding is closed correctly.
3.3 Service interval display: resetting serv‐
ice
WARNING
Risk of injury as engine of high-voltage vehicle can start un‐
expectedly!
♦ Observe warnings for high-voltage system:
♦ For work that must be performed with the ignition switched
on ⇒ page 11 .
Audi A8 2010 ➤
Maintenance - Edition 11.2014
26 3. Maintenance