Hardware Installation Manual 28 Document #: LTRT-10391
Mediant 500 E-SBC
5.6 Connecting to the Power Supply
The device receives power from a standard alternating current (AC) electrical outlet. The
connection is made using the supplied AC power cord.
Table 5-3: Power Specifications
Physical Specification Value
Input Voltage
Single universal AC power supply 100 to 240V
AC Input Frequency
50 to 60 Hz
AC Input Current
0.8A
Max. Power Consumption
20W
Warnings:
The device must be connected to a socket-outlet providing a protective earthing
connection.
Use only the AC power cord that is supplied with the device.
ご注意
本製品に添付の電源ケーブルは、Mediant 500 E-SBC に専用設計されているため、汎用
性がありません. 本電源ケーブルを他の機器に使用されないよう、ご注意ください.
To connect the device to the power supply:
1. Connect the line socket of the AC power cord (supplied) to the device's AC power
socket (labeled 100-240V~50-60 Hz 0.8A), located on the rear panel.
Figure 5-8: Connecting to the Power Supply
2. Connect the plug at the other end of the AC power cord to a standard electrical outlet.
3. Press the power switch to on (I) position so that the device receives power; the
POWER LED on the front panel is lit green (for more information, see Section 3.2.2.4
on page 17).